Variable Frequency Series Resonance Test System with 0 to 800kV RMS Stepless Regulation and 20Hz-300Hz Adjustable Operating Band for AC Resonant Test

Sansion Power Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Variable Frequency Series Resonance Test System with 0 to 800kV RMS Stepless Regulation and 20Hz-300Hz Adjustable Operating Band for AC Resonant Test

  • 1
  • 2
  • 3

Model Number : SXBP

MOQ : 1 Set

Rated Output Voltage : 0 to 800kV RMS, Stepless Regulation

Frequency Regulation Resolution : 0.01Hz Step Adjustment, Stability Accuracy ≤0.01%

Output Frequency : 20Hz - 300Hz Adjustable Operating Band

Delivery Time : 30 Working Days

Quality Factor : Full Load System Quality Factor Min.20

Certification : CE/SGS/EMS/ISO 9001

Brand Name : Sansion

Place of Origin : China

Payment Terms : T/T,L/C

Working Power Supply : 1Ph 220V AC / 3Ph 380V AC

Packaging Details : Plywood Case

Output Waveform : Sine Output, Total Harmonic Distortion ≤1%

Contact Now

General Information

The SXBP Series Variable Frequency Series Resonant Test System is an integrated solution for AC withstand voltage testing of high-voltage electrical equipment. Developed for power utilities, electrical equipment manufacturers, testing laboratories and engineering contractors, the system is designed to address different voltage levels and capacitive load requirements through application-specific configuration.​
By combining a variable frequency power supply, excitation transformer, resonant reactors and a control and measurement unit, the SXBP Series provides a coordinated solution for generating high AC test voltages under suitable resonant conditions.

System Components
  • Variable Frequency Power Supply: Provides adjustable-frequency excitation for establishing the resonant operating condition.​
  • Excitation Transformer: Supplies the excitation voltage required by the resonant circuit.​
  • Resonant Reactor: Provides the inductive element needed to establish series resonance with the test object.​
  • Control and Measurement Unit: Supports operating parameter adjustment and relevant electrical measurements.​
Product Highlights
1.Variable-Frequency Series Resonance

The system adjusts its operating frequency to establish resonance between the inductive reactance of the resonant reactor and the capacitive reactance of the test object. The available frequency range depends on the selected model.​

2.Modular Equipment Configuration

The variable frequency power supply, excitation transformer and resonant reactors form the main functional components. Their ratings and arrangement can be selected according to the required test voltage and capacitive load.​

3.Application-Specific System Selection

System selection takes into account test voltage, test-object capacitance, required operating frequency, test duration and site conditions. This helps align the equipment configuration with the actual testing task.​

4.Integrated Control and Measurement

The control and measurement unit supports system operation and monitoring of relevant test parameters. Specific control, measurement and protection functions depend on the supplied configuration.​

5.Adaptable to Different Testing Environments

The modular arrangement can support laboratory and field-testing applications when the selected system is appropriate for the site power supply, installation conditions, transportation requirements and safety arrangements.

Typical Testing Applications
  • Power Cable Withstand Testing​
    Configured for applicable AC withstand voltage tests on medium- and high-voltage power cables. Cable length, capacitance, rated voltage and test duration are important selection parameters.​
  • Gas-Insulated Switchgear Testing​
    Suitable configurations can be evaluated for AC insulation testing of GIS and related high-voltage assemblies according to the specified test procedure.​
  • Transformer Insulation Testing​
    The system can be considered for compatible AC withstand voltage testing applications involving transformers and related electrical equipment.​
FAQ
Q:What factors should be considered when selecting a resonant test system?

The main selection factors include the required AC test voltage, test-object capacitance, operating frequency, test duration and site power supply. The equipment configuration should be evaluated based on the complete testing requirements rather than the voltage rating alone.​

Q:Why is variable-frequency technology used in series resonant testing?

Variable-frequency technology allows the operating frequency to be adjusted to establish resonance between the inductive reactance of the resonant reactor and the capacitive reactance of the test object. This enables the system to accommodate different capacitive loads within its specified operating range.

Variable Frequency Series Resonance Test System with 0 to 800kV RMS Stepless Regulation and 20Hz-300Hz Adjustable Operating Band for AC Resonant Test

Product Tags:

800kV Stepless Regulation Resonant Test System

      

20Hz-300Hz Adjustable Band Series Resonant Test Set

      

Sine Output AC Resonant Test System

      
Quality Variable Frequency Series Resonance Test System with 0 to 800kV RMS Stepless Regulation and 20Hz-300Hz Adjustable Operating Band for AC Resonant Test for sale

Variable Frequency Series Resonance Test System with 0 to 800kV RMS Stepless Regulation and 20Hz-300Hz Adjustable Operating Band for AC Resonant Test Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sansion Power Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)