Partial Discharge : 1–3 pC at Rated Voltage
Delivery Time : 30 Working Days
Voltage Level : 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV, 1000 kV
Brand Name : Sansion Power
Capacity : 50–2000 kVA
Model Number : SXGTU
Voltage Boosting : Single Stage
MOQ : 1
Resonance : Power Frequency / Variable Frequency
Place of Origin : China
Primary Voltage : 0.35–10 kV
Payment Terms : L/C,T/T
Temperature Rise : ≤65 K at Rated Current for 60 Minutes at 50 Hz
Packaging Details : Plywood Case
High Voltage Generation : High Voltage Transformer / Series Resonance
Certification : CE/SGS/EMS/ISO 9001
SXGTU GIS Partial Discharge Withstand Voltage Test Device
The SXGTU GIS Partial Discharge and AC Withstand Test System is designed for high voltage insulation testing. The high voltage section is fully sealed inside a shielded space, providing a safer and more reliable test structure. The overall partial discharge can be controlled within 1–3 pC at rated voltage under normal environmental conditions.
The system is available in voltage levels from 100 kV to 1000 kV and capacities from 50 kVA to 2000 kVA. High voltage can be generated through a high voltage transformer or series resonance at power frequency or variable frequency. All voltage boosting methods use single-stage boosting without cascade connection. The compact structure requires less installation space and offers convenient connection with the test object.
|
Parameter |
Specification |
|
Model |
SXGTU |
|
Voltage Level |
100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV, 1000 kV |
|
Capacity |
50–2000 kVA |
|
High Voltage Generation |
High Voltage Transformer / Series Resonance |
|
Resonance |
Power Frequency / Variable Frequency |
|
Voltage Boosting |
Single Stage |
|
Primary Voltage |
0.35–10 kV |
|
Partial Discharge |
1–3 pC at Rated Voltage |
|
Temperature Rise |
≤65 K at Rated Current for 60 Minutes at 50 Hz |
Q1: What voltage levels are available?
A1: The available voltage levels are 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV and 1000 kV.
Q2: What is the partial discharge level?
A2: The overall partial discharge can be controlled within 1–3 pC at rated voltage under normal environmental conditions.
Q3: What voltage boosting methods are available?
A3: The system supports high voltage transformer boosting and series resonance.
Q4: Does the system require cascade boosting?
A4: No. All voltage boosting methods use single-stage voltage boosting without cascade connection.

|
|
SF6 GIS Partial Discharge and AC Withstand Test System for High Voltage Electrical Equipment Gas Insulated Switchgear Insulation Testing Images |